Cookie Img
Home » Products » Hot Air Blowers » Hot Air Boiler 6 TO 8 Laks KCAL / HR

Hot Air Boiler 6 TO 8 Laks KCAL / HR

Hot Air Boiler 6 TO 8 Laks KCAL / HR
Hot Air Boiler 6 TO 8 Laks KCAL / HR
Product Code : VPM 14 (6 to 8 Laks)
Product Description

Hot Air Boiler 6 TO 8 Laks KCAL / HR

 


  • This is indirect hot air generator mainly used for air heating process requirement. Capacity starts from 100000 kcal/hour to 2000000 kcal/hour & above at 250’C as per customer’s requirement.

  • This equipment consisting of 4 paths flew gas system.

  • Radiant path constructed from SS 410 of shell to shell and another 2nd, 3rd & 4th pass constructed from ERW IS 1239 tubes.

  • Furnace made from MS structure and high aluminium bricks line, high grade CI casted fire bars equipment is fully insulated with high grade density glass wool.

  • System is controlled through the control panel with simulation of ID & FD fans maintain the air temperature and smoke temperature at prefix set value.



                                                               MACHINE TECHNICAL SPECIFICATION

 NO

  SPECIFICATION

         MODEL- 1

   MODEL- 2

  MODEL- 3

  MODEL- 4

  1

  CAPACITY kcal/hr

             2 lack/hr

      4 lack/hr

    6 lack/hr

     8 lack/hr

  2

  TOTAL POWER-HP

               15-hp

         25-hp

     35-hp

       38-hp

  3

  HEAT CONSUMPTION - K CAL/HR





  4

  TEMP RANGE ‘C

               100’c

        100’c

     100’c

       100’c

  5

  AIR FLOW M3/HR

           7309 M3/HR

  14619 M3/HR

 21990 M3/HR

 29200 M3/HR

  6

  PROCESS FAN HP

              12.5 HP

        20 HP

    30 HP

       30 HP

  7

  FURNACE FD+ ID FAN

             3 HP

       5 HP

    5 HP

     + 7.5 HP

  8

  SIZE L X B X H – IN MTR

  4.5mtrx2.5mtrx2mtr

  6mtrx 3mtr x 2.5mtr

  7mtrx 3mtr x 4mtr

 8mtrx 3mtr x  2.5mtr

  9

  EFFICIENCY- %

           70%(+/- 3)

    70%(+/- 3)

  70%(+/- 3)

    70%(+/- 3)


  ACTUAL ENERGY CONSUMPTION/HR





  1

  POWER- MC LOAD – ELEC UNIT/HR






  POWER- HEAT EQUIP LOAD - ELEC UNIT/HR





  2

  FUEL CONSUMPTION – WOOD KG/HR  (CV-2200)

        90 KG/HR

    180KG/HR

  300KG/HR

   360KG/HR


  - LIGNITE KG/HR(CV-3400)

        65 KG/HR

    125KG/HR

  210KG/HR

    255KG/HR

 


OPTYTECH ENGINEERS

Contact Us

( *represents compulsory fields )

Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.